Welcome to the official website of Qingdao Puren Instrument Co., Ltd
Online Message
|
Contact us
Website map
RSS
XML
400-0823518
Home
About Puren
Company Overview
Company Honor
Development Path
Company Culture
Enterprise Performance
Recruitment
Brand Advantage
Product Advantages
Technical Advantages
Service
Quality Assurance
Cooperation Cases
News
Company News
Product News
Industry News
Media Focus
Products
Ion Chromatograph
Online ion chromatograph
Portable ion chromatograph
Atmospheric aerosol line detector
IC Autosampler
Accessories
Precipitation Sampler
Applications
Hot Applications
Industry Standards
Technical Support
Operating Instructions
Installation and Commissioning
Daily Maintenance
Troubleshooting
Sample Preparation
Contact
Contact us
Customer Message
中文
Applications
Location:
Home
>
Applications
>
Hot Applications
Industry Standards
Determination of Melamine in Milk by Total Ion Chromatograph
2017-03-03
───────────────────────────── No. Retention Time Name Concentration Peak Area ───────────────────────────── 1 7.186Melamine 0.1 83623 ───────────────────────────── total 0.1 83623 ...
Analysis of the Standard Spectrum of Melamine Added to Milk
2017-03-03
──────────────────────────── No. Retention Time Name Peak Area Peak Height ──────────────────────────── 1 7.247Melamine 2282032 61273 ──────────────────────────── total 2282032 61273 ...
Single channel dual channel (conductance - UV) signal output
2017-03-03
No. Retention time Name Concentration (ppm) Peak area peak height ────────────────────────────────── 1 7.575Melamine 1 1035065 26571 ────────────────────────────────── total 1 1035065 26571 ...
Determination of Diethylene Glycol in a Pharmaceutical by Io
2017-03-03
...
Determination of Anions in Peanut Oil
2017-03-03
Determination of Conventional Anions in Peanut Oil Column: NJ-SA-4A, 250mm × 4.6mm Detector: Suppresses the conductivity detector Eluent: carbonate solution Column temperature: 25 ° C Injection volume: 200uL ──────────────────────── No. Retention Time Name Peak Area Peak Height ────────────────────────...
Electrochemical Detection of Iodide and Thiocyanate in Milk
2017-03-03
1 IntroductionMilk in the thiocyanate and iodine ions in infant food safety is an important test items. December 12, 2008 published "may be illegal in the food to add non-food substances and easy to abuse the list of food additives (first batch)" clearly defined thiocyanate is illegal addition of substances, but no corresponding GB test method. Thiocyanate has been used by unscrupulous dairy farme...
Analysis of Low Intake Disinfection by - products
2017-03-03
Column: Shodex 52 4E Eluent: 3.6.mmol / lia2CO3 Flow rate: 0.7 ml / min Column temperature: 36 ° C Suppression current: 60mA Injection volume: 200ml Serial number Retention time / min name Peak area Theoretical plate number Minimum detection limit / mg / L 1 6.128 F 279163 3947 0.2 2 8.918 CLO2 1464 11056 1.5 3 9.665 BRO3 1464 11427 1.7 4 10.793 CL 320318 9955 0.27 5 13.989 NO2 91035 13370 0.81 6...
A Simple Method for the Determination of Hexavalent Chromium
2017-03-03
Hexavalent chromium on the human body toxicity, drinking water health standards for drinking water in the hexavalent chromium concentration can not exceed 0.05mg / L. For the detection of hexavalent chromium in drinking water, ion exchange chromatography can be used, UV detection. Chromatographic conditions and test results are as follows: Chromatographic conditions: Column: PR-SA-8A (250mm * 4.6m...
1
2
3
4
5
6
7
8
9
10
11